banner

Blog

Jun 23, 2023

A high

Scientific Reports volume 12, Article number: 3299 (2022) Cite this article

3595 Accesses

26 Citations

3 Altmetric

Metrics details

Evaluation of extracellular domain of human epidermal growth factor receptor-2 (HER2-ECD) oncomarker status is an impressive factor in screening, diagnosing and monitoring early-stage breast cancer (BC). Electrochemical aptamer-based nanobiosensor with high sensitivity and selectivity for quantitative and qualitative measurement of HER2-ECD oncomarker was developed. In this study, the nanocomposite made by distinct materials included reduced graphene oxide nano-sheets (rGONs) and rhodium nanoparticles (Rh-NPs) on the graphite electrode (GE) surface. This structure resulted in amplified electrochemical activity, high surface area, stability, and bio-compatibility. Each of the steps of preparing nanomaterials and setting up biosensor were carefully examined by analytical and electrochemical techniques. Various modified electrodes were constructed and analyzed in terms of electrochemical performance, morphology, size, and shape of nanomaterials. The GE-based aptasensor had a noteworthy and conducive results against HER2-ECD with a wide dynamic range of 10.0–500.0 ng/mL, a low limit of detection (LOD) of 0.667 ng/mL (significantly less than the clinical cut-off), and a low limit of quantification (LOQ) of 2.01 ng/mL. The benefits provided by this aptasensor such as broad dynamic range, high sensitivity, selectivity, stability, reproducibility, and low cost suggest tremendous potential for non-invasive detection and monitoring of the HER2-ECD levels of BC care and clinical diagnosis.

Nowadays, the incidence of cancer diseases is a major threat to human health1. According to statistics reported in 2021, BC with a population of 2.26 million people has the highest number of cancer patients worldwide2,3. BC is a complex disease that causes the severe alterations in the levels of genes, proteins, and metabolites4. It is impossible to provide adequate and timely treatmentwithout a thorough diagnosis. Sensitive, selective, and rapid diagnostic testing methods not only pave the way for a more effective treatment, but also have a great impact on preventing a variety of cancers, especially BC5. Therefore, Medical screening and early detection of BC through quantitative oncomarker measurements are essential to timely follow-up, enhance survival rate, and reduce mortality6. Definitive procedures for diagnosing primary stages of BC include mastography, biopsy, ultrasound imaging, and magnetic resonance imaging (MRI). Furthermore, techniques based on gene expression and quantitation such as immunohistochemistry (IHC), radioimmunoassay (RIA), and enzyme immunoassay (EIA) are used to diagnose BC in women7,8,9. However, most of these techniques face several limitations including high complexity, being too expensive, and a significant reduction in sensitivity and specificity10,11,12. For these reasons, researchers have prioritized the development of non-invasive, inexpensive, sensitive, and user-friendly diagnostic technologies to monitor BC at specific times for effective treatment13. As a result, novel analytical techniquessuch as point-of-care testing (POCT) for this disease in its early stages provide faster results at the point of care delivery in resource-constrained settingenabling timely and proper treatment.

Electrochemical biosensors have been utilized as a promising diagnostic tool to qualitatively and quantitatively determination of oncomarkers due to their fast reaction, ease of use, low cost, and low detection limit. In fabricating new electrochemical biosensors, it is crucial to select a flawless electrode matrix to optimize the electrochemical response14,15,16,17. Identifying the oncomarkers used for early detection, recurrence, and monitoring of BC metastasis are necessary. HER2-ECD is one of these oncomarkers in the process of BC diagnosis and treatment through HER2-targeted therapy. The primary mechanism of HER2-ECD receptor overexpression is amplification of its oncogene found on chromosome 17q12. The presence of this oncomarker is essential for the growth and advancement of certain aggressive malignancies such as lung, ovarian, breast, gastric, and oral cancers18. HER2-ECD concentration in blood of healthy people and BC patients is in the range of 4.0 to 14 ng/mL and 15 to 75 ng/mL, respectively. which can be used for diagnosis and active surveillance of patients at risk or in treatment19. HER2-ECD with higher-than-normal levels are called HER2-positive or HER2+. People who are identified as HER2+ in BC diagnostic processes, enter the treatment protocol with Herceptin. Herceptin is a monoclonal antibody (Ab) specifically designed and approved to target HER2 receptors on the surface of BC cells and block them from receiving growth signals20.

Hybridization of carbon nanomaterials with noble metal nanoparticles providesadvanced biosensors that have preferable optical, mechanical, chemical, and electrical properties21. rGONs possesses a high specific surface area, high electrical conductivity (as compared with GONs), excellent biocompatibility, and abundant chemically active sites for chemical functionalization and catalysis. Due to their superior physical and chemical features, rGONs have been extensively used in flexible electronics, batteries, supercapacitors, sensors, and so on. However, rGONs have a propensity to agglomerate or restack through van der Waals forces and pi-pi stacking interactions. Stabilizers or chemical modifiers are usually exploited to enhance the dispersibility of rGONs, but these methods often diminish their analytical performance. Recently, various methods have been developed to prevail over rGONs agglomeration. One of the new strategies involves the assembly of metal nanoparticles (NPs) onto graphene to form hybrid nanocomposites22,23.

Rh-NPs have emerged as a desirable and promising strategy to decorate rGONs due to their advantageous properties including a large specific surface area, excellent electrical conductivity, good bio-compatibility, high biomolecular adsorption, and chemical stability24. these nanoparticles play a critical role as self-assembled, conductive, and stable monolayers on the surface of nanocomposite.

Various nanomaterials have been investigated to design and fabricate electrochemical biosensors to detect cancerous oncomarkers including multi-branched gold nano-shells and octreotide functionalized Pt nano-flakes modified GCEs for detection of Somatostatin receptors25 and nanocomposites of carbon nanotube and polyaniline prepared on the carbon electrode for detecting vascular endothelial growth factor (VEGF)26. Biosensors constructed with disposable electrodes such as graphitic electrodes offer low detection limit, easier assembly of metallic NPs, good reproducibility, low contamination and excellent bio-compatibility with antibodies and aptamers27,28. Some types of GEs used to diagnostic biosensors are: GE modified by gold NPs for detection of SARS-CoV-229, GE modified with iron oxide/polypyrrole/palladium nanocomposite for detection of methotrexate and folic acid30, GE immobilized by antibodies for detection of P5331, GE modified by fullerene (C60) for detection of Tumorigenicity 232, and GE modified by Fe3O4@ZIF-8 NPs for detection of sumatriptan33.

Aptamers possess an extensive variety of medical applications in different fields includingtherapeutic solutions, diagnostic services, and biosensors34. Their recognition properties are determined not only by their specific sequences, but also by their ability to fold into distinct shapes with specified functions. These outstanding features make the aptamers as good candidates for the bio-recognition agents of electrochemical biosensors35,36.

In this study, we exploited an electrochemical aptasensing platform and employed a novel and efficient procedure to modify GE surface using rGONs and Rh-NPs functionalized with anti-HER2 aptamers for detection and quantification of HER2-ECD oncomarker. To the best of our knowledge, Rh-NPs have not been used for biosensor fabrication especially in diagnosis of cancerous oncomarkers (Scheme 1).

Schematic presentation of fabrication procedure of aptasensor for detecting HER2-ECD oncomarker: (1) the synthesis of rGONs, (2) the process of formation of Rh-NPs, (3) the immobilization of aptamer strands, and (4) the HER2-ECD detection using the proposed aptasensor.

We synthesized rGONs on the GE by an eco-friendly in situ electrochemical method. To produce multi-layers of GONs on the GE surface, electrochemical oxidation and exfoliation were performed for four sequential sweeps in PBS (pH 6.5) at anodic potentials ranging from 0.0 to + 3.0 V. As shown in the cyclic voltammetry (CV) curves in Fig. 1a, electrochemical oxidation of graphite structure eventuated during the positive sweep at around + 1.4 V. During the electrochemical oxidation process, the van der waals and other cohesive forces in the midst of graphene sheets decreased and the layers separated and spaced apart with the help of gas evolution. Thus, intercalation and exfoliation of graphite to GONs occurred. Intercalating compounds comprising a diverse spectrum of hydrophilic oxygenated functional groups (i.e. hydroxyl, epoxy, carbonyl, carboxylic acid) were produced which the majority of them situated at the edges of basal planes37,38. CV scanning in cathodic potentials ranging from 0.0 to − 1.60 V for five sequential sweeps in PBS (pH 6.9) was used to electrochemically reduce the GONs to rGONs (Fig. 1b). The curve in the first cyclic voltammogram of electrochemical reduction shows a significant and broad cathodic peak current at about − 1.350 V. This significant peak is most likely due to reduction of oxygenated functional groups on the GONs-modified GE surface. This reduction can not be related to reduction of H2O molecules to hydrogen because it occurs at greater negative potentials. In the second CV, the reduction current peak decreases dramatically at negative potentials and almost disappears after the second scan. This finding suggests that a significant diminish in surface-oxygenated functional groups at GONs occurs and converts to rGONs irreversibly and rapidly. As a result, the exfoliated GONs can be reduced using electrochemical approach at negative potentials39,40. Accordingly, the number of voltammetric cycles, scan rate, pH, and temperature of the supporting electrolyte were among the characteristics effective in converting graphite to rGONs. This technique was more efficient when performed at middle scan rate (50 mV/s) and multiple voltammetric cycles to provide sufficient time for production of rGONs from graphite in two steps of electrochemical oxidation and reduction. At slightly acidic pH (6.5), the condition for oxidation process and formation of GONs were more favorable. However, it was better to have a slightly higher pH (6.9) during the reduction and conversion of GONs to rGONswhich reduces and eliminates the functional groups more easily and quickly. These experiments had the best results at ambient temperature (20 to 24 °C).

(a) CV curves of GONs synthesis on the GE for four consecutive sweeps in PBS (pH 6.5), (b) CV curves of rGONs synthesis on the GONs-modified GE for five consecutive sweeps in PBS (pH 6.9). Scan rate: 50 mV/s.

Noble metal nanoparticles (NMNPs) are efficiently produced by reducing the equivalent metallic salt in water41,42. Rh-NPs were synthesized using electrochemical reduction. In this procedure, Rh-NPs were grown on the surface under optimum conditions by applying CV technique in potentials between 0.0 and − 800.0 mV for four successive sweeps43. As a result, the rGONs-modified GE was adorned with Rh-NPs (Rh-NPs/rGONs/GE). For the synthesis of NMNPs, the rGONs provide numorous nucleating sites. Consequently, different procedures for the synthesis of graphene hybrids with noble metals such as Au, Ag, Rh, Pd, and Pt have been developed and investigated for design of electrochemical biosensors, catalysis, fuel cells, and so on44. The 2D structure of nano-sheets of graphene in these hybrid nanocomposites not only provides a perfect framework for anchoring the metal nanostructures, but also improve the electrical conductivity and interfacial electron transport liberated by these adherent NPs, limiting nanoparticle aggregation45.

Field emission scanning electron microscopy (FE-SEM), Energy-dispersive X-ray spectroscopy (EDS), EDS Mapping, and Fourier transform infrared-attenuated total reflectance (FTIR-ATR) spectroscopy were used to analyze the as-prepared nanomaterials. All results indicated that the nanomaterials were successfully synthesized.

The functional groups were identified using FTIR-ATR spectroscopic studies. The FTIR-ATR spectra of graphite, GONs, and rGONs are shown in Fig. 2. The characteristic peak at 1460 cm−1 corresponds to C=C skeletal vibration of graphitic domain. Several peaks in the GONs spectrum show oxygen-containing functional groups. The characteristic peaks of O–H (3391 cm−1), C=O (1732 cm−1), C–O (1556 cm−1), C–OH (1317 cm−1), and C–O (1162 cm−1) are thought to be assigned for stretching hydroxyl group in carboxylic acid, carboxyl group, carboxylic acid, and carbonyl group, respectively. The presence of oxygen functional groups in FTIR-ATR of GONs spectra indicates that the flake graphite has been oxidized to GONs. These peaks do not appear in the graphite spectra, showing the existence of a significant number of oxygen functional groups (–COOH and C=O near the sheet edge, –OH and C–O groups in epoxy on the GONs sheet basal planes) added during the oxidation step. There is no noticeable peak after reducing and converting GONs to rGONs, indicating that the rGONs are fully reduced. Carbon–oxygen functional groups such as carboxyl groupsremain in the rGONs structure with faint peaks.

FTIR-ATR spectra of unmodified, GONs-modified, and rGONs-modified graphite electrodes (GEs).

Figure 3a,b shows the FE-SEM images of Rh-NPs with spherical morphology extremely dispersed with nanoscale sizes that cover rGONs on the surface of graphite electrode. The elemental composition of the surface of Rh-NPs/rGONs/GE was also investigated by EDS mapping analysis, showingthat the modified electrode surface is coated with Rh-NPs (Fig. 3c). The EDS profile of carbon, oxygen, and rhodium (Rh) corroborates the successful formation of high-purity components (Fig. 3d).

(a,b) FE-SEM images of Rh-NPs/rGONs/GE with nanometer-sized, (c) EDS mapping analysis of Rh element on the surface of rGONs-modified GE, (d) EDS elemental analysis obtained from Rh-NPs/rGONs/GE.

Electrochemical Impedance Spectroscopy (EIS), differential pulse voltammetry (DPV), and CV are essential techniques utilized in the development of biosensors and the evaluation of their performance46. The CVs of different modified GEs are shown in Fig. 4a. Electrochemical output of the modified GEs is compared with that of the unmodified GE. The CV technique is extensively implemented for exploratory purposes. The use of this technique in biosensor development is common since the CV technique possesses significant information such as types of redox processes present in the analysis and the process reversibility in reactions47. Redox peaks in the cyclic voltammogram correlated with the oxidation of ferrocyanide ion and reduction of ferricyanide ion on the GE surface are seen at 0.26 and 0.17 V, respectively. The peak current densities for the Rh-NPs/rGONs/GE are proportionately higher than those of the rGONs/graphite and bare GEs. This amplification in electrochemical signal could be attributed to increased conductivity in the presence of Rh-NPs and enhanced diffusive mass transport of the anion [Fe(CN)6]4− to the Rh-NPs/rGONs/GEs surface compared with other unmodified and modified GEs. All electrochemical characterizations of the Rh-NPs/rGONs/GEs were carried out in PBS containing 5.0 mM Potassium ferri-/ferro-cyanide (+ 0.1 M KCl) as a solution of standard electrochemical probe.

(a) Cyclic voltammograms of different unmodified and modifiedGE, (b) CV graphs of Rh-NPs/rGONs/GE based on various scan rates of 5, 15, 30, 50, 100, 150, 200, and 400 mVs−1, (c) Calibration curves of the redox peak current densities against the square root of the sweep rate based on cyclic voltammogram characterization of Rh-NPs/rGONs/GE, (d) DPV curves of different unmodified and modified GEs, (e) EIS Nyquist plots of different unmodified and modified GEs in PBS containing 5.0 mM ferri-/Ferro-cyanide (1:1) ion redox as an electrochemical probe, (f) Different concentrations of aptasensor against current densities, g) incubation binding time against current densities.

Figure 4b demonstrates the peak currents in cyclic voltammogram for redox states in the presence of standard electrochemical probe at scan rates from 5.0 to 400.0 mV/s. As can be seen in Fig. 4c, there is a relationship of linearity between the square root of scan rate against the redox of peak current density. When the scan rate increases, the anodic and cathodic peak current densities elevate significantly at the same time with an average correlation coefficient (R2) value of 0.990, stating the redox reaction is diffusion controlled48.

The differential pulse voltammograms of unmodified and modified GEs are shown in Fig. 4d. After modifying the electrode with rGONs and Rh-NPs, peak current densities increase significantly. Electrochemical methods based on the pulse techniques like DPV are more sensitive than the linear sweep methods due to possible minimization of the interference capacitive current. The pulse techniques are mostly employed for quantitative determination since DPV has a significantly lower detection limit than other well-known electrochemical techniques owing to a greater signal-to-noise ratio.

EIS is a sensitive and precise electrical resistance measurement techniquegenerally employed for the characterization of modified electrode surfaces or significant change of bulk properties49. The electron transfer characteristics between electrolyte and electrode interfacial surface were checked using EIS in a solution of standard electrochemical probe. The charge transfer resistance (Rct) controls the kinetics of electron transfer of Potassium ferri-/ferro-cyanide ionic redox reaction at the electrolyte–electrode interface. When the GE is modified by rGONs and Rh-NPs (denoted as Rh-NPs/rGONs/GE), it exhibits a semicircle at the high frequencies including a small Rct value that is the result of fast electron transfer50. Finally, among the different constructed GEs with various modifications, Rh-NPs/rGONs/GE was used as an optimal platform of aptasensor due to its high performance compared with others.

The predicted secondary structure of anti-HER2 aptameric strand shows that double stem-loops and a random sequence are in its primary stem-loop structure anticipated to be bound to the particular place of HER2-ECD. Transducer layer is extremely important for immobilization of the aptamer strand and stabilization of the formed G-quadruplex, affecting the sensitivity and selectivity of the aptasensor. It seems that nanomaterials are ideal platforms for immobilization of anti-HER2 aptamer strands due to their privileged bio-compatibility as well as extremely large surface area to volume ratio51. The interaction between HER2-ECD and aptameric strand leads to opening the anti-HER2 hairpin duplex and the formation of aptamer/HER2-ECD complex52. In this study a remarkable decrease in CV and DPV peak current measurements in aptasensor was seen. This is due to the fact thataptamers are insulating compounds that the phosphate groups in their structures would be ionized into plenty negative charges in aqueous solution that barricade the transfer of electron on the surface of electrode owing to the intense electrostatic repulsion with ferri-/ferro-cyanide ionic redox available in electrochemical probe53. The difference of electrochemical current density obtained by changing oncomarker concentration compared with BSA stabilization was usedas the measurement system displayed as Δj. Then, the effect of two important parameters i.e., anti-HER2 aptamer concentration and incubation binding time for HER2-ECD oncomarker was explored. First, the MPA/Rh-NPs/rGONs/GEs which have already been activated by EDC/NHS were submerged in different concentrations of anti-HER2 aptamer (5, 15, 30, 50, and 100 nM), dipped in 5% BSA solution, and incubated with 300 ng/mL of HER2-ECD. As clearly exhibited in Fig. 4f, an increase in the concentration of anti-HER2 aptamer up to 50 nM enhances the current density. However, no significant change is observed for aptamer concentration greater than 50 nM since the modified surface of electrode is thoroughly saturated with anti-HER2 aptamer54. Accordingly, a concentration of 50 nM anti-HER2 aptamer was selected as the optimal concentration. Second, to gain the best incubation binding time of the HER2-ECD, the aptasensor in concentration of 300 ng/mL of was incubated for 10, 20, 40, 60, 90, and 120 min. The intensity of current density (j) raised with increasing the incubation binding time and then stayed almost steady after 40 min incubation because the surface of electrode was saturated. For this reason, the most favorable incubation time was determined to be 40 min (Fig. 4g).

Since the selected anti-HER2 aptamer strand was made up of 54 oligonucleotide bases (5′-(NH2-(CH2)6-GGG CCG TCG AAC ACG AGC ATG GTG CGT GGA CCT AGG ATG ACC TGA GTA CTG TCC)-3′)51,55, optimizing the sensitive layer to bind the aptamer strand to surface of modified GE and immobilize the generated G-quadruplex was critical. Given their high bio-affinity and intrinsic bio-compatibility, rGONs and Rh-NPs could be used as a platform for immobilizing anti-HER2 aptamer strands, followed by HER2-ECD recognition via G-quadruplex formation between aptamer strands and HER2-ECD oncomarker. As a consequence, the aptasensor based on BSA/Apt/MPA/Rh-NPs/rGONs/GE was employed to evaluate each stage of the detection procedure of various oncomarkers.

The proposed aptasensor was also employed to detect HER2-ECD oncomarker at various doses. For this purpose, HER2-ECD oncomarker was tested at concentrations ranging from 0.010 to 500.0 ng/mL. Then, the interaction results were measured using the DPV technique (Fig. 5a). As demonstrated in Fig. 5b, by rising the concentration of HER2-ECD, the current density increases. The electrochemical response of the aptasensor towards HER2-ECD is in the linear range of 10.0 to 500.0 ng/mL. The linear relationship between Δj and Log [CHER2-ECD] was: Δj (µA cm−2) = − 42.023 + 75.297 Log [CHER2-ECD] (ng/mL) and an R2 of 0.9937, where [CHER2-ECD] is the concentration of HER2-ECD. The LOD and LOQ calculated using this equation is 0.665 ng/mL and 2.01 ng/mL, respectively. This aptasensor provides a satisfactory performance compared with the present HER2-ECD biosensors described in the literature (Table 1). The significant stability of the aptasensor can be ascribed to the BSA/MPA/Rh-NPs/rGONs/GE and strong covalent binding of anti-HER2 aptamer to the modified electrode via MPA linker. Therefore, the results demonstrates good performance of aptasensor even at lower HER2-ECD oncomarker concentrations that can be employed to monitor small changes in oncomarker concentration in many forms of cancer during the primary stage of disease. The selectivity of electrochemical aptasensor was also investigated using different interfering agents such as carcinoembryonic antigen (CEA), prostate-specific antigen (PSA), and Human Serum Albumin (HSA). The results show that PSA and CEA have a slight change in current density (Fig. 5c) whereas the HER2-ECD oncomarker has a significant change. Four electrodes were made to evaluate reproducibility (Fig. 5d). These findings show that the aptasensor is exceedingly selective and stable for direct detection of the HER2-ECD oncomarker. The long-term stability is an important parameter in clinical applications. As shown in Fig. 5e, the signal changes after 14 days are minimal and this indicates that the aptasensor has maintained its detection performance and stability compared with the first day with relative standard deviation (RSD) 4.3%. Therefore, the developed aptasensor has a high level of reliability and efficiency.

(a) DPV responses of aptasensor with different concentrations of HER2-ECD (0.01, 0.1, 1, 10, 15, 30, 50, 100, 200, 500 ng/mL); (b) Dependence of current density on changes in HER2-ECD concentration (inset: the linear portion of calibration curve); (c) Selectivity of aptasensor in contact with 100 ng/mL HER2-ECD, CEA, PSA, and HSA oncomarkers; (d) Reproducibility of aptasensor for detection of 100 ng/mL HER2-ECD with 4 electrodes, separately; (e) Stability of aptasensor for detection of 300 ng/mL HER2-ECD within 14 days, Each measurement was repeated at least 4 times.

The practical applicability of the introduced aptasensor was examined and approved by the electrochemical analyses of oncomarkers present in patient serum samples. The aptasensor was employed for detection and quantification of HER2-ECD in serum samples from five patients. The results (Table 2) were in agreement with commercially available ELISA kit. Hence, it can be deduced that the proposed aptasensor is reliable and sensitive enough for clinical application.

In summary, a novel and well-organized aptasensor was constructed for detection and determination of HER2-ECD oncomarker. The collaborative effect of rGONs and Rh-NPs can boost electrochemical signal and sensitivity by increasing conductivity and specific surface area. Furtheremore, the stability of the formed G-quadruplex increased through strong covalent interactions between the aptameric strand and the oncomarker. Accordingly, a low value of LOD was obtained equal to 0.667 ng/mL. The results of this study confirmed the successful performance of the constructed aptasensor. This promising electrochemical aptasensor could be feasibly applied as a platform for diagnosis and monitoring of a wide variety of oncomarkers in different cancers.

The pencil graphite type HB with a diameter of 2.0 mm was purchased from Rotring Co. Ltd, Germany. 3-Mercaptopropionic acid (MPA), N-HydroxySuccinimide (NHS), Bovine Serum Albumin (BSA), Human Serum Albumin (HSA) 1-ethyl-3-(3-dimethylaminopropyl) Carbodiimide hydrochloride (EDC), Rhodium(III) Chloride (RhCl3, 98%), and HER2 ELISA assay Kit (for serum, plasma, urine, and etc.) was procured from Sigma-Aldrich, USA. Potassium ferricyanide (k3Fe(CN)6), and Potassium ferrocyanide (K4Fe(CN)6) were obtained from Merck, Germany. Anti-HER2 aptamer specifically bind to HER2-ECD oncomarker was obtained from Bio Basic Inc, Canada. The sequence of Amine-terminated HER2 DNA aptamer (Apt) consists of 54-mer oligonucleotide bases is 5′-(NH2-(CH2)6-GGG CCG TCG AAC ACG AGC ATG GTG CGT GGA CCT AGG ATG ACC TGA GTA CTG TCC)-3′. This anti-HER2 DNA aptamer sequence was selected by serial evolution of ligands in vitro by exponential enrichment (SELEX) process51,55. The recombinant human HER2/ErBb2/CD340 oncomarker was procured from Sigma-Aldrich, USA. Sulfuric Acid (H2SO4 98%), Hydrochloric Acid (HCl 37%), and Ethanol (99.8%), were purchased from Merck, Germany. Other analytical grade reagents were obtained of the highest level of purity and all required solutions were prepared from double distilled water.

All electrochemical measurement include CV, DPV, and EIS were carried out using a potentiostat–galvanostat Palmsense BV PGSTAT, with a compliance voltage of 30 V (Echo chemie, Netherlands) by a customary three-electrode cell arrangement. The graphite with various modifications was employed as a working electrode. The desired amplitude of potentials were measured against an Ag/AgCl in a solution containing saturated KCl, acting as the reference electrode. A platinum wire electrode was used, functioning as counter electrode. A freshly polished and prepared electrode was used for each experiment. The measurements were performed exactly after applying the three electrodes and immersing them in the probe solution. All electrochemical experiments were carried out in PBS (0.1 M, pH 7.4) containing of 5.0 mM K4[Fe(CN)6]/K3[Fe(CN)6] (1:1 ratio) and 0.1 M KCl as ion redox probe couple. The ferri-/ferro-cyanide ionic redox pair in buffered media is frequently employed as a standard probe in electrochemical studies. The [Fe(CN)6]3−/4− ionic redox process involves a single electron transfer and exhibits quasi-reversible kinetic characteristics under the condition that the electron transfer in a complete cycle is less resistant63.

CV curves were recorded with a scan rate of 50 mV/s and within − 0.2 to + 0.6 V vs Ag/AgCl. DPV was measured between − 0.2 to + 0.6 V, with an amplitude of 50 mV, a pulse width of 0.2 s. EIS measurements were carried out in the frequency range of 0.01 to 50 kHz with a direct potential of 0.22 V as a bias potential and an amplitude of 5.0 mV.

We used a simple, efficient, and novel in situ redox electrochemical approach to directly produce rGONs-modified GEs. Briefly, Cyclic Voltammetry (CV) sweeping the potential from 0.0 to + 3.0 V was achieved for a series of four successive sweeps in PBS (pH 6.5) to form few-layer GONs on the surface of electrode. Later, CV sweeps carried out from 0.0 to − 1.60 V in PBS (pH 6.9) for electrochemical reduction of exfoliated GONs in five successive cycles to obtain rGONs-GE39,64,65.

Rh-NPs were electrochemically synthesized using an electrolyte solution containing 0.01 M RhCl3 and 0.01 M KCl. CV technique was employed in the potential range from 0.0 to − 800.0 mV for four successive sweeps. The electrolyte solution was provided in double-distilled water to a final volume of 10 ml. The cathodic reduction of rhodium ions at room temperature occurs as follows:

In order to prepare the electrode used in aptasensor, the Rh-NPs/rGONs modified GE was suspended in 20 mM MPA solution dissolved in ethanol/water (3:1 V/V) at pH 6.8 under shaking (75 rpm) at room temperature for 18 h. Thus, MPA/Rh-NPs/rGONs/GE was rinsed with double-distilled water. The optimal concentration of the MPA was used as a linker to bind modified electrode to the bio-recognition agent (anti-HER2 aptamer). The carboxyl-functionalized MPA can strengthen the binding of amino-functionalized strands of aptamer as well as enhance electrochemical activity of the aptasensor66. The MPA/Rh-NPs/rGONs/GE was incubated in PBS containing 0.05 M NHS and 0.20 M EDC for 1 h at 8 °C in order to activate its surface. For covalent conjugation of activated surface with amine group (-NH2) of functionalized anti-HER2 aptamer, the modified electrode was dipped in PBS buffer containing 50 nM anti-HER2 aptamer at room temperature for 1 h, for amide bond formation. Furthermore, Apt/MPA/Rh-NPs/rGONs/GE was immersed in BSA solution with concentration of 5% at the temperature of 37 ºC under 5% CO2 atmosphere and humidity with 95% for 5 min to block the activated carboxyl functional groups on the surface of modified electrode that are not bonded with the amino functional groups of anti-HER2 aptamer. The functionalized GE was rinsed with PBS for several times. Finally, the constructed aptasensor was employed to detect different oncomarkers.

8.0 g NaCl, 200 mg KCl, 1.44 g Na2HPO4 and 245 mg KH2PO4 were combined to make a 1.0 L phosphate buffered solution (PBS, 0.1 M, pH 7.4). In the aforesaid PBS, a stock solution of aptamer (100 M), HER2-ECD, CEA, PSA, and HSA was produced and kept at 4 °C. In addition, the solution was diluted with PBS to achieve the appropriate concentration. For real-time analysis, the human serum was diluted 20-fold with 0.01 M PBS solution (pH 7.4). Also, for the synthesis of rGONs, the pH of the 0.1 M PBS was adjusted by 0.01 M HCl.

Zahra, Q. U. A., Khan, Q. A. & Luo, Z. Advances in optical aptasensors for early detection and diagnosis of various cancer types. Front. Oncol. 11, 632165–632165 (2021).

Article PubMed PubMed Central Google Scholar

Sung, H. et al. Global cancer statistics 2020: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA: Cancer J. Clin. 71, 209–249 (2021).

Google Scholar

Ferlay, J. et al. Cancer statistics for the year 2020: An overview. Int. J. Cancer 149, 778–789 (2021).

Article CAS Google Scholar

DeBerardinis, R. J. & Chandel, N. S. Fundamentals of cancer metabolism. Sci. Adv. 2, e1600200 (2016).

Article PubMed PubMed Central ADS Google Scholar

Shen, H. et al. Ultrasensitive aptasensor for isolation and detection of circulating tumor cells based on CeO2@ Ir nanorods and DNA walker. Biosens. Bioelectron. 168, 112516 (2020).

Article CAS PubMed Google Scholar

Ginsburg, O. et al. Breast cancer early detection: A phased approach to implementation. Cancer 126, 2379–2393 (2020).

Article PubMed Google Scholar

Vajhadin, F. et al. Electrochemical cytosensors for detection of breast cancer cells. Biosens. Bioelectron. 151, 111984 (2020).

Article CAS PubMed Google Scholar

Prabhakar, B., Shende, P. & Augustine, S. Current trends and emerging diagnostic techniques for lung cancer. Biomed. Pharmacother. 106, 1586–1599 (2018).

Article CAS PubMed Google Scholar

Altintas, Z. & Tothill, I. Biomarkers and biosensors for the early diagnosis of lung cancer. Sens. Actuators B Chem. 188, 988–998 (2013).

Article CAS Google Scholar

Mittal, S., Kaur, H., Gautam, N. & Mantha, A. K. Biosensors for breast cancer diagnosis: A review of bioreceptors, biotransducers and signal amplification strategies. Biosens. Bioelectron. 88, 217–231 (2017).

Article CAS PubMed Google Scholar

Marques, R. C., Viswanathan, S., Nouws, H. P., Delerue-Matos, C. & González-García, M. B. Electrochemical immunosensor for the analysis of the breast cancer biomarker HER2 ECD. Talanta 129, 594–599 (2014).

Article CAS PubMed Google Scholar

Cui, F., Zhou, Z. & Zhou, H. S. Measurement and analysis of cancer biomarkers based on electrochemical biosensors. J. Electrochem. Soc. 167, 037525 (2019).

Article Google Scholar

Cordaro, A., Neri, G., Sciortino, M. T., Scala, A. & Piperno, A. Graphene-based strategies in liquid biopsy and in viral diseases diagnosis. Nanomaterials 10, 1014 (2020).

Article CAS PubMed Central Google Scholar

Khan, M., Hasan, M., Hossain, S., Ahommed, M. & Daizy, M. Ultrasensitive detection of pathogenic viruses with electrochemical biosensor: State of the art. Biosens. Bioelectron. 166, 112431 (2020).

Article CAS PubMed PubMed Central Google Scholar

Chen, L.-C. et al. Improving the reproducibility, accuracy, and stability of an electrochemical biosensor platform for point-of-care use. Biosens. Bioelectron. 155, 112111 (2020).

Article CAS PubMed Google Scholar

Liu, S., Yang, Z., Chang, Y., Chai, Y. & Yuan, R. An enzyme-free electrochemical biosensor combining target recycling with Fe3O4/CeO2@ Au nanocatalysts for microRNA-21 detection. Biosens. Bioelectron. 119, 170–175 (2018).

Article CAS PubMed Google Scholar

Choi, H. et al. electrochemical immunoassay for determination of glycated albumin using nanozymes. Sci. Rep. 10, 1–12 (2020).

Google Scholar

Burstein, H. J. The distinctive nature of HER2-positive breast cancers. N. Engl. J. Med. 353, 1652–1654 (2005).

Article CAS PubMed Google Scholar

Arya, S. K. et al. Capacitive aptasensor based on interdigitated electrode for breast cancer detection in undiluted human serum. Biosens. Bioelectron. 102, 106–112 (2018).

Article CAS PubMed Google Scholar

Elamir, A. et al. Ultrasound-triggered herceptin liposomes for breast cancer therapy. Sci. Rep. 11, 1–13 (2021).

Article Google Scholar

Hameed, S. & Bhattarai, P. Novel nanomaterials for biosensor development. In Nanobiosensors: From Design to Applications (eds Wu, A. & Khan, W. S.) 45–72 (Wiley, 2020).

Chapter Google Scholar

Lan, Q. et al. Platinum nanoparticle-decorated graphene oxide@ polystyrene nanospheres for label-free electrochemical immunosensing of tumor markers. ACS Sustain. Chem. Eng. 8, 4392–4399 (2020).

Article CAS Google Scholar

Yang, Y., Huang, H., Yang, C. & He, H. Ultrafine Rh-decorated 3D porous boron and nitrogen dual-doped graphene architecture as an efficient electrocatalyst for methanol oxidation reaction. ACS Appl. Energy Mater. 4, 376–383 (2021).

Article CAS Google Scholar

Karakulina, A., Gopakumar, A., Fei, Z. & Dyson, P. J. Chemoselective reduction of heteroarenes with a reduced graphene oxide supported rhodium nanoparticle catalyst. Catal. Sci. Technol. 8, 5091–5097 (2018).

Article CAS Google Scholar

Cong, C. et al. Sensitive measurement of tumor markers somatostatin receptors using an octreotide-directed Pt nano-flakes driven electrochemical sensor. Talanta 208, 120286 (2020).

Article CAS PubMed Google Scholar

Park, Y., Hong, M.-S., Lee, W.-H., Kim, J.-G. & Kim, K. Highly sensitive electrochemical aptasensor for detecting the VEGF165 tumor marker with PANI/CNT nanocomposites. Biosensors 11, 114 (2021).

Article CAS PubMed PubMed Central Google Scholar

Cunha-Silva, H. & Arcos-Martinez, M. J. A disposable rhodium nanoparticle-modified screen-printed sensor for direct determination of bromide anions. Sens. Actuators B Chem. 282, 603–608 (2019).

Article CAS Google Scholar

Torres-Rivero, K., Florido, A. & Bastos-Arrieta, J. Recent trends in the improvement of the electrochemical response of screen-printed electrodes by their modification with shaped metal nanoparticles. Sensors 21, 2596 (2021).

Article CAS PubMed PubMed Central ADS Google Scholar

de Lima, L. F., Ferreira, A. L., Torres, M. D., de Araujo, W. R. & de la Fuente-Nunez, C. Minute-scale detection of SARS-CoV-2 using a low-cost biosensor composed of pencil graphite electrodes. Proc. Natl. Acad. Sci. 118, e2106724118 (2021).

Article PubMed PubMed Central Google Scholar

Tajik, S., Beitollahi, H., Shahsavari, S. & Nejad, F. G. Simultaneous and selective electrochemical sensing of methotrexate and folic acid in biological fluids and pharmaceutical samples using Fe3O4/ppy/Pd nanocomposite modified screen printed graphite electrode. Chemosphere 291, 132736 (2021).

Article PubMed ADS Google Scholar

Nohwal, B., Chaudhary, R. & Pundir, C. Amperometric detection of tumor suppressor protein p53 via pencil graphite electrode for fast cancer diagnosis. Anal. Biochem. 639, 114528 (2021).

PubMed Google Scholar

Demirbakan, B. & Sezgintürk, M. K. An impedimetric biosensor system based on disposable graphite paper electrodes: Detection of ST2 as a potential biomarker for cardiovascular disease in human serum. Anal. Chim. Acta 1144, 43–52 (2021).

Article CAS PubMed Google Scholar

Tajik, S., Shahsavari, M., Sheikhshoaie, I., Garkani Nejad, F. & Beitollahi, H. Voltammetric detection of sumatriptan in the presence of naproxen using Fe3O4@ ZIF-8 nanoparticles modified screen printed graphite electrode. Sci. Rep. 11, 1–12 (2021).

Article Google Scholar

Figueroa-Miranda, G. et al. Aptamer-based electrochemical biosensor for highly sensitive and selective malaria detection with adjustable dynamic response range and reusability. Sens. Actuators B Chem. 255, 235–243 (2018).

Article CAS Google Scholar

Wu, C., Offenhäusser, A. & Mayer, D. A highly sensitive amperometric aptamer biosensor for adenosine triphosphate detection on a 64 channel gold multielectrode array. Phys. Status Solidi (a) 217, 1900925 (2020).

Article CAS ADS Google Scholar

Chen, Y., Xiang, J., Liu, B., Chen, Z. & Zuo, X. Gold nanoparticle-engineered electrochemical aptamer biosensor for ultrasensitive detection of thrombin. Anal. Methods 12, 3729–3733 (2020).

Article CAS PubMed Google Scholar

Liu, F. et al. Synthesis of graphene materials by electrochemical exfoliation: Recent progress and future potential. Carbon Energy 1, 173–199 (2019).

Article ADS Google Scholar

Yu, W., Sisi, L., Haiyan, Y. & Jie, L. Progress in the functional modification of graphene/graphene oxide: A review. RSC Adv. 10, 15328–15345 (2020).

Article CAS ADS Google Scholar

Rabieh, S., Koushanpour, A. & Tajabadi, F. Green and straightforward modification of graphite electrode via in situ synthesis of graphene nanosheets for quantifying prazosin hydrochloride in urine samples and pharmaceutical formulations. Electroanalysis 27, 2377–2386 (2015).

Article CAS Google Scholar

Xia, L. et al. Cr2O3 nanoparticle-reduced graphene oxide hybrid: A highly active electrocatalyst for N2 reduction at ambient conditions. Inorg. Chem. 58, 2257–2260 (2019).

Article CAS PubMed Google Scholar

Habibullah, G., Viktorova, J. & Ruml, T. Current strategies for noble metal nanoparticle synthesis. Nanoscale Res. Lett. 16, 1–12 (2021).

Article Google Scholar

de Oliveira, P. F., Torresi, R. M., Emmerling, F. & Camargo, P. H. Challenges and opportunities in the bottom-up mechanochemical synthesis of noble metal nanoparticles. J. Mater. Chem. A 8, 16114–16141 (2020).

Article Google Scholar

Mousavi, F., Shamsipur, M., Taherpour, A. A. & Pashabadi, A. A rhodium-decorated carbon nanotube cathode material in the dye-sensitized solar cell: Conversion efficiency reached to 11%. Electrochim. Acta 308, 373–383 (2019).

Article CAS Google Scholar

Zou, C. E. et al. Electrochemical synthesis of gold nanoparticles decorated flower-like graphene for high sensitivity detection of nitrite. J. Colloid Interface Sci. 488, 135–141 (2017).

Article CAS PubMed ADS Google Scholar

Samantara, A. K., Tripathy, R. K. & Behera, J. Hybrid nanocomposites based on graphene and gold nanoparticles: From preparation to applications. In Graphene and Nanoparticles Hybrid Nanocomposites: From Preparation to Applications (eds Qaiss, A. K. et al.) 197 (Springer, 2021).

Chapter Google Scholar

Brazaca, L., Ribovski, L., Janegitz, B. & Zucolotto, V. Medical Biosensors for Point of Care (POC) Applications 229–254 (Elsevier, 2017).

Book Google Scholar

Karunakaran, C., Rajkumar, R. & Bhargava, K. Biosensors and Bioelectronics 1–68 (Elsevier, 2015).

Book Google Scholar

Dai, Y., Abbasi, K., DePietro, M., Butler, S. & Liu, C. C. Advanced fabrication of biosensor on detection of Glypican-1 using S-Acetylmercaptosuccinic anhydride (SAMSA) modification of antibody. Sci. Rep. 8, 1–7 (2018).

Article Google Scholar

Islam, M. N. & Channon, R. B. Bioengineering Innovative Solutions for Cancer 47–71 (Elsevier, 2020).

Book Google Scholar

Guo, C. et al. Aptamer-templated silver nanoclusters embedded in zirconium metal–organic framework for bifunctional electrochemical and SPR aptasensors toward carcinoembryonic antigen. ACS Appl. Mater. Interfaces 9, 41188–41199 (2017).

Article CAS PubMed Google Scholar

Gu, C. et al. Bimetallic ZrHf-based metal-organic framework embedded with carbon dots: Ultra-sensitive platform for early diagnosis of HER2 and HER2-overexpressed living cancer cells. Biosens. Bioelectron. 134, 8–15 (2019).

Article CAS PubMed Google Scholar

Tabasi, A., Noorbakhsh, A. & Sharifi, E. Reduced graphene oxide-chitosan-aptamer interface as new platform for ultrasensitive detection of human epidermal growth factor receptor 2. Biosens. Bioelectron. 95, 117–123 (2017).

Article CAS PubMed Google Scholar

Wang, Z. et al. NH 2-Ni-MOF electrocatalysts with tunable size/morphology for ultrasensitive C-reactive protein detection via an aptamer binding induced DNA walker–antibody sandwich assay. J. Mater. Chem. B 6, 2426–2431 (2018).

Article CAS PubMed Google Scholar

Zhu, Y., Chandra, P. & Shim, Y.-B. Ultrasensitive and selective electrochemical diagnosis of breast cancer based on a hydrazine–Au nanoparticle–aptamer bioconjugate. Anal. Chem. 85, 1058–1064 (2013).

Article CAS PubMed Google Scholar

Niazi, J. H., Verma, S. K., Niazi, S. & Qureshi, A. In vitro HER2 protein-induced affinity dissociation of carbon nanotube-wrapped anti-HER2 aptamers for HER2 protein detection. Analyst 140, 243–249 (2015).

Article CAS PubMed ADS Google Scholar

Freitas, M., Neves, M. M., Nouws, H. P. & Delerue-Matos, C. Quantum dots as nanolabels for breast cancer biomarker HER2-ECD analysis in human serum. Talanta 208, 120430 (2020).

Article CAS PubMed Google Scholar

Ou, D. et al. A dual-aptamer-based biosensor for specific detection of breast cancer biomarker HER2 via flower-like nanozymes and DNA nanostructures. J. Mater. Chem. B 7, 3661–3669 (2019).

Article CAS Google Scholar

Freitas, M., Nouws, H. P., Keating, E. & Delerue-Matos, C. High-performance electrochemical immunomagnetic assay for breast cancer analysis. Sens. Actuators B Chem. 308, 127667 (2020).

Article CAS Google Scholar

Shamsipur, M., Emami, M., Farzin, L. & Saber, R. A sandwich-type electrochemical immunosensor based on in situ silver deposition for determination of serum level of HER2 in breast cancer patients. Biosens. Bioelectron. 103, 54–61 (2018).

Article CAS PubMed Google Scholar

Li, X., Shen, C., Yang, M. & Rasooly, A. Polycytosine DNA electric-current-generated immunosensor for electrochemical detection of human epidermal growth factor receptor 2 (HER2). Anal. Chem. 90, 4764–4769 (2018).

Article CAS PubMed Google Scholar

Ehzari, H., Samimi, M., Safari, M. & Gholivand, M. B. Label-free electrochemical immunosensor for sensitive HER2 biomarker detection using the core-shell magnetic metal-organic frameworks. J. Electroanal. Chem. 877, 114722 (2020).

Article CAS Google Scholar

Centane, S. & Nyokong, T. The antibody assisted detection of HER2 on a cobalt porphyrin binuclear framework and gold functionalized graphene quantum dots modified electrode. J. Electroanal. Chem. 880, 114908 (2021).

Article CAS Google Scholar

Varyambath, A., Tran, C. H., Song, W. L. & Kim, I. Hyper-cross-linked polypyrene spheres functionalized with 3-aminophenylboronic acid for the electrochemical detection of diols. ACS Omega 2, 7506–7514 (2017).

Article CAS PubMed PubMed Central Google Scholar

Zeng, F. et al. In situ one-step electrochemical preparation of graphene oxide nanosheet-modified electrodes for biosensors. Chemsuschem 4, 1587–1591 (2011).

Article CAS PubMed Google Scholar

Guo, H.-L., Wang, X.-F., Qian, Q.-Y., Wang, F.-B. & Xia, X.-H. A green approach to the synthesis of graphene nanosheets. ACS Nano 3, 2653–2659 (2009).

Article CAS PubMed Google Scholar

Wang, C. et al. Nitrogen-doped graphene quantum dots@ SiO2 nanoparticles as electrochemiluminescence and fluorescence signal indicators for magnetically controlled aptasensor with dual detection channels. ACS Appl. Mater. Interfaces 7, 26865–26873 (2015).

Article CAS PubMed Google Scholar

Download references

The authors are grateful for financial support from Nano Drug Delivery Research Center, Health Technology Institute, Kermanshah University of Medical Science, Kermanshah, Iran (Grant No. 990192; IR.KUMS.REC.1398.1245). Also wish to express our sincere gratitude and thanks to Dr. Keivan Majidzadeh-a, and Dr. Ramin Sarrami-Forooshani from BCRC, Motamed Cancer Institute, ACECR, Tehran, Iran, for their support in laboratory facilities and real serum samples.

Nanobiotechnology Department, Faculty of Innovative Science and Technology, Razi University, Kermanshah, Iran

Mahdi Sadeghi & Soheila Kashanian

Faculty of Chemistry, Sensor and Biosensor Research Center (SBRC), Razi University, Kermanshah, Iran

Soheila Kashanian

Nano Drug Delivery Research Center, Health Technology Institute, Kermanshah University of Medical Science, 6734667149, Kermanshah, Iran

Elham Arkan

Biomaterials and Tissue Engineering Research Group, Interdisciplinary Technologies Department, Breast Cancer Research Center (BCRC), Motamed Cancer Institute, ACECR, Tehran, Iran

Seyed Morteza Naghib

Nanotechnology Department, School of Advanced Technologies, Iran University of Science and Technology (IUST), 1684613114, Tehran, Iran

Seyed Morteza Naghib

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

M.S. established the experimental procedures an wrote the manuscript draft. S.K., S.M.N. and E.A. wrote and revised the manuscript and were supervisors.

Correspondence to Soheila Kashanian, Seyed Morteza Naghib or Elham Arkan.

The authors declare no competing interests.

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and Permissions

Sadeghi, M., Kashanian, S., Naghib, S.M. et al. A high-performance electrochemical aptasensor based on graphene-decorated rhodium nanoparticles to detect HER2-ECD oncomarker in liquid biopsy. Sci Rep 12, 3299 (2022). https://doi.org/10.1038/s41598-022-07230-3

Download citation

Received: 15 November 2021

Accepted: 15 February 2022

Published: 28 February 2022

DOI: https://doi.org/10.1038/s41598-022-07230-3

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

Cancer Nanotechnology (2023)

Cancer Nanotechnology (2022)

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.

SHARE